Slab 2 – 1-Stage Space Heat with Slab Maximum
Press and hold the MODE and VIEW buttons simultaneously for 5 seconds to enter the setup mode.
SETUP: SYSTEM
SETUP: SYSTEM
Heat Sys Type:
Slab MAX T:
SLAB 2
122
o
1 STG SPACE HEAT BY SLAB
WITH SLAB MAX (W1)
Press To Continue
Heat Sys Type: SLAB 2
Slab MAX T: Select 39°122° F (39° 50° C). Used to
prevent the floor from becoming too hot on long heat calls.
NOTE: Slab mode 2 requires an air temperature source and a
slab remote sensor (CHV-RSS, sold separately).
SETUP: SYSTEM PERFORMANCE
SETUP: SYSTEM PERF
Heat Anticipator:
5
ADJUSTS HEAT SHUTOFF DYNAMICS
Press To Continue
Heat Anticipator: Select 1 6.
Low number = more frequent cycles, faster response.
High number = less frequent cycles, slower response.
SETUP: HUMIDITY OPTIONS
SETUP: HUM OPTS
Show Hum Mode Pg:
Show Hum View Pg:
Cold Weather Comp:
Y
Y
N
SYSTEM ENABLE/DISABLE
PAGE
SETUP: HUM OPTS
Invert Hum Output Y
Call FAN in HUM: N
INVERTED HUM RELAY LOGIC
HUM ABOVE SP = ENERGIZED
Press To Continue
Show Hum Mode Pg and Show Hum View Pg: Select Y to
show humidity page in normal operation.
Cold Weather Comp: Modifies the humidifier output to prevent
condensation on the windows. Requires an outdoor
temperature source (CHV-THSAT or CHV-TSTAT with
CHV-RTHS, CHV-RTS or CHV-RSS, sensors sold
separately).
Invert Hum Output: Reverses the logic controlling the
switching of the HUM relay (NO/NC). May be useful when
using to control a dehumidifier.
NOTE: Most dehumidifier applications require the default
setting.
Call FAN in HUM: Makes a fan call during humidity calls
instead of waiting for a heating or cooling call to trigger fan.
NOTE: Most dehumidifier applications automatically trigger
fan operation.
NOTE: This setting is only useful for humidity calls with
normal (non-inverted) logic.