Crestron SWAMP(I)-24X8 Sonnex™ Multiroom Audio System
Each network device must have a unique Net ID.
The Net ID can be set from the SWAMP-24X8’s front panel or with Crestron
Toolbox. For more details, refer to “Set the Cresnet ID” on page 38 or the Crestron
Toolbox help file.
IP ID
The IP ID is set from the SWAMP-24X8’s front panel or within the
SWAMP-24X8’s IP table using Crestron Toolbox. For more details, refer to “Set the
IP ID” which starts on page 39 or the Crestron Toolbox help file. The IP IDs of
multiple SWAMP-24X8 devices in the same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the SIMPL
Windows program.
Each device using IP to communicate with a control system must have a
unique IP ID.
Installation
Ventilation
The SWAMP-24X8 should be used in a well-ventilated area. The venting holes
should not be obstructed under any circumstances.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consider using
forced air ventilation and/or incrementing the spacing between units to reduce
overheating. Consideration must be given if installed in a closed or multi-unit rack
assembly since the operating ambient temperature of the environment may be greater
than the room ambient temperature. Contact with thermal insulating materials should
be avoided on all sides of the unit.
Rack Mounting
The SWAMP-24X8 can be mounted in a rack or stacked with other equipment. Two
“ears” are provided with the SWAMP-24X8 so that the unit can be rack mounted.
These ears must be installed prior to mounting. Complete the following procedure to
attach the ears to the unit. The only tool required is a #1 or #2 Phillips screwdriver.
WARNING: To prevent bodily injury when mounting or servicing this unit in a
rack, take special precautions to ensure that the system remains stable. The following
guidelines are provided to ensure your safety:
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
NOTE: Feet are preinstalled for tabletop mounting or stacking. If the unit is to be
rack mounted, the feet are not required and can be removed to provide more space in
the rack.
NOTE: Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit (e.g. use of power strips).
To install the ears:
1. Using a #1 or #2 Phillips screwdriver, remove the feet installed on the
bottom of the SWAMP-24X8.
Operations Guide – DOC. 7049B Sonnex™ Multiroom Audio System: SWAMP(I)-24X8 17