Crestron QM-MD8x8 QuickMedia Distribution System
down at the copper connections, pin 1 is on the far right. The following table lists the
pin assignments on the RJ-45 connector.
Pin and Pair Assignment
RJ-45
PIN #
CAT5E
PAIR #
WIRE
COLORS
(568B)
QM ASSIGNMENT
RGB AND AUDIO
QM ASSIGNMENT
COMPOSITE,
S-VIDEO AND AUDIO
1 2 WHITE/ORANGE - RGB RED - CHROMINANCE
2 2 ORANGE + RGB RED + CHROMINANCE
3 3 WHITE/GREEN - RGB GREEN - LUMINANCE
4 1 BLUE + AUDIO + AUDIO
5 1 WHITE/BLUE - AUDIO - AUDIO
6 3 GREEN + RGB GREEN + LUMINANCE
7 4 WHITE/BROWN - RGB BLUE - COMPOSITE
8 4 BROWN + RGB BLUE + COMPOSITE
NOTE: When using Crescat-QM wiring, a cable containing four wires is included
for making Cresnet connections.
Identity Code
All equipment and user interfaces within the network require a unique identity code
(Net ID). These codes are two-digit hexadecimal numbers from 03 to FE. The Net ID
of each unit must match an ID code specified in the SIMPL Windows program.
Refer to “Setting the Net ID in Device Settings” on page 21 for details of the SIMPL
Windows procedure.
Refer to the note on page 24 for a
definition of Viewport.
The Net ID of the MD8x8 has been factory set to 06. The Net IDs of multiple
MD8x8s in the same system must be unique. Net IDs are changed from a personal
computer (PC) via the Crestron Viewport.
NOTE: For detailed information on establishing communication between the PC and
control system, refer to “Communication Settings” on page 25. If communication
cannot be established, refer to the “Troubleshooting Communications” section in the
respective Operations Guide for the control system.
There are two different methods—Method A or Method B—for setting the Net ID:
Method A (Cresnet address-settable ID), described below, applies to devices in a
Cresnet system with a 2-Series control system that require a single unit be the only
network device connected to the control system.
Method B (Touch Settable ID or TSID), which begins on the following page, applies
to all TSID-ready devices in a Cresnet system with 2-Series control system upgrade
file (CUZ) version 3.029 or later. TSID functionality makes it possible for the
control system to recognize a network device via its serial number, which is stored in
the device’s memory. This method does not require that any devices be disconnected
from the network; Net IDs may be set with the entire Cresnet system intact. This
method requires the use of the Crestron Viewport version 3.35 or later.
Use the appropriate method to set the Net ID.
Method A (Cresnet address-settable ID)
1. Ensure that the device requiring a Net ID change is the only unit connected
to the control system.
2. Open the Crestron Viewport.
Operations Guide - DOC. 6260 QuickMedia Distribution System: QM-MD8x8 13