Crestron DigitalMedia Room Controller DM-RMC-100 Installationsanleitung Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
Crestron DM-RMC-100-S DigitalMedia 8G™ Fiber Receiver 100
Setup
Network Wiring
When wiring the DM network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
CAUTION: Failure to use Crestron power supplies could cause equipment
damage or void the Crestron warranty.
Provide sufficient power to the system.
For DigitalMedia 8G Fiber wiring, CresFiber 8G is recommended. Refer to
the following table for the maximum transmission distance of CresFiber 8G
and other fiber optic cable.
DigitalMedia 8G Fiber Wiring and Maximum Transmission Distance
CABLE TYPE MAXIMUM TRANSMISSION DISTANCE
CresFiber 8G
1000 feet (~300 meters)
CresFiber 500 feet (~150 meters)
Generic OM3 500 feet (~150 meters)
For complete wiring guidelines, refer to the latest version of the Crestron
DigitalMedia Design Guide (Doc. 4789).
The DM-RMC-
100-S also uses high-speed Ethernet for communications between the
device and a control system, computer, media server, and other IP-based devices.
For general information on connecting Ethernet devices in a Crestron system, refer to
the latest version of the Crestron e-Control
®
Reference Guide (Doc. 6052), which is
available from the Crestron Web site (
www.crestron.com/manuals). For information
specifically related to Ethernet connectivity using DigitalMedia devices, refer to the
latest version of the Crestron IP Considerations Guide (Doc. 4579), which is also
available from the Crestron Web site (
www.crestron.com/dmresources).
Identity Code
NOTE: In the SIMPL™ Windows program, the IP ID of the DM-RMC-100-S is
assigned automatically and does not require additional programming when the
DM-RMC-100-S is dropped onto an output card of a DM switcher. Use the
information below when the DM-RMC-100-S is dropped directly into an Ethernet
slot on the control system in SIMPL Windows without a DM switcher.
The IP ID is set within the DM-RMC-100-S IP table using Crestron Toolbox™.
For information on setting an IP table, refer to the Crestron Toolbox help file.
The IP IDs of multiple DM-RMC-100-S devices in the same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the SIMPL
Windows program.
Each device using IP to communicate with a control system must have a
unique IP ID.