70 •• Appendices Installation & Reference Guide — DOC. 5823
Enabled scroller signal
Description “Handshake” response to the Enable signal.
Direction
Server to System
Type
Digital
Value Asserted in response to assert of Enable signal.
De-asserted in response to de-assertion of Enable signal.
Expected Reply
None
Comments
Although this signal is often ignored, in a proper implementation, when enabling
the signal block (usually upon arrival to a certain touchscreen page), the System
should:
(1) Wait for assertion of Enabled before issuing any other scroller signals.
(2) Indicate an error condition if assertion of Enabled does not occur after a
certain amount of time (typically 30 seconds).
When disabling the signal block (usually upon arrival to a certain touchscreen
page), the System should:
(3) Wait for de-assertion of Enabled before leaving touchscreen page.
(4) Indicate an error condition if de-assertion of Enabled does not occur after a
certain amount of time (typically 30 seconds).
The demos implement (1) and (3) but not (2) and (4).
See Also Enable signal