Crestron e-control Database Manager SW-DBM
56 Appendices Installation & Reference Guide — DOC. 5823
When these signals are defined in the scroller signal block, the server uses them.
When not defined, however, the server sends the signal via the “owning” signal
block. If the signal is not defined there either, or the scroller has no owner, the signal
is sent to the COM Settings signal block. If the signal is also undefined in the
COM Settings signal block, the signal is lost (not sent).
COM Settings Signal Block Summary
The system block contains two Ping and two Pong signals. One pair consists of a
send (Ping) and receive (Pong) from the Server’s point of view; and the other, a
send (Ping) and receive (Pong) from the Systems’ point of view. This
accommodates pinging from either (a) Systems to the Server or (b) vice versa.
Signal Block Signal Name Direction Type
COM Settings
BlankAll
server-to-system
D
COM Settings
Done
server-to-system
D
All
ErrNumber
server-to-system
A
All
ErrString
server-to-system
S
All
ErrTrigger
server-to-system
D
COM Settings
PingSvr
system-to-server
D
COM Settings
PingSys
server-to-system
D
COM Settings
PongSvr
server-to-system
D
COM Settings
PongSys
system-to-server
D
COM Settings
RefreshAll
server-to-system
D
Scroller Signal Block Summary
Some signals shown below cannot be defined in an e-mailer scroller (a restricted
version of a standard scroller).
Signal Block Signal Name Direction Type
Custom Scroller
Blank
system-to-server
D
Custom Scroller
ClearRec
system-to-server
D
Custom Scroller
CloseRec
system-to-server
D
Custom Scroller
Cols
system-to-server
A
Custom Scroller
Data
d
server-to-system
S
Custom Scroller
DeleteAllRecs
system-to-server
D
Custom Scroller
DeleteRec
system-to-server
D
All Scrollers
Done
server-to-system
D
All Scrollers
Enable
system-to-server
D
All Scrollers
Enabled
server-to-system
D
Custom Scroller
ErrNumber
server-to-system
A
Custom Scroller
ErrString
server-to-system
S
Custom Scroller
ErrTrigger
server-to-system
D
All Scrollers
First
system-to-server
D
Custom Scroller
GoLevel
v
system-to-server
D
Custom Scroller
GoLevelEcho
v+1
server-to-system
S
All Scrollers
Last
system-to-server
D
All Scrollers
List
r
or List
r,c
server-to-system
S
Seitenansicht 55