Wired Touchpanels Crestron Series 1600
Power Management Submenu
NOTE: Display backlight requires warm-up time. A display reaches 80% of its final
level in five minutes and full brightness in 20 minutes.
Power Management Submenu
The touchpanel display hardware life can be lengthened by turning off the backlight
when the touchpanel is inactive. The MANAGE POWER button is located in the
top left corner of the Setup Menu. Selection of this button changes the touchpanel
display to reveal the Power Management Submenu, shown to the left.
BACKLIGHT TIMEOUT is displayed on the Timeout Submenu. This setting turns
the backlight off when the touchpanel is inactive for a specified time frame (shown
in minutes). When the touchpanel is activated, the last screen to be displayed
reappears. A two-minute BACKLIGHT TIMEOUT is shown in the illustration.
Minutes can vary from 0 to 120, where 0 disables the timeout. DOWN and UP
buttons decrease and increase the timeout, respectively.
After the timeout parameter has been set, touch the SAVE TIMEOUT button in the
lower left corner of the screen to save the new settings. Touch the RETURN button,
located in the lower right corner of the screen, to display the Setup Menu.
Interface Submenu
Interface Submenu
The touchpanel communicates with a control system to activate other controls or to
display feedback from components within the system. The communication interface
must be correctly specified or communication will not occur. To set communication
parameters select the INTERFACE button located centrally in the top row of the
Setup Menu and display the Interface Submenu, shown to the left.
The Cresnet network identity number (NET ID) is displayed in the top left corner of
the Interface Submenu. NET ID is the two-digit hexadecimal number represented by
## in the figure for illustrative purposes. The hexadecimal number can range from 03
to FE and must correspond to the NET ID set in the SIMPL Windows program.
Matching NET IDs between touchpanel and program are required if data is to be
successfully transferred or new touchpanel screens are to be loaded. NET ID is
factory set to 03.
Two side-by-side buttons adjacent to the hexadecimal display, < CRESNET ID and
CRESNET ID >, decrease and increase the NET ID by one, respectively.
The touchpanel usually communicates with a Cresnet system. Occasionally the
touchpanel can be used in a local demo mode where it merely displays various
menus, but does not communicate with Cresnet system. In local mode, the directory
buttons change pages, but buttons requiring feedback do not work. Two centrally
located buttons on the Interface Submenu, CRESNET II and LOCAL, determine
communication mode. Select LOCAL to set the touchpanel into demo mode and
CRESNET II for normal Cresnet communication mode. Text within the selected
button changes color from black to red (for CT models) or black to gray (for LC
models). Communication mode is factory set to CRESNET II.
NOTE: RS-232 communication requires installation of a custom hardware option.
Two side-by-side buttons, RS-232 ON and RS-232 OFF, are centrally located on the
Interface Submenu. RS-232 is just for external control applications. Panel loading is
always available; RS-232 does not have to be on.
If the touchpanel is utilized in a system with optional RS-232 communication, ensure
that the RS-232 ON button is selected. Additional RS-232 parameters must be set
with the RS-232 Screen since alternative parameters may be required for successful
10 Series 1600 Wired Touchpanels Operations & Installation Guide - DOC. 5836A