Wired Touchpanels Crestron Series 1600
NOTE: All network wiring must consist of two twisted-pairs. One twisted pair is
the +24V conductor and the GND conductor and the other twisted pair is the Y
conductor and the Z conductor.
NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to
avoid nicking the conductors. Twist together the ends of the wires that share a pin on
the network connector, and tin the twisted connection. Apply solder only to the ends
of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Insert the tinned connection into the Cresnet connector and tighten the retaining
screw. Repeat the procedure for the other three conductors.
Hardware Hookup
Due to physical differences, the lectern and tiltcase models require different hookup
procedures. Furthermore, the lectern model installs simply and cleanly into existing
or newly constructed walls (or other suitable mounting surface). Back box and
drywall mounting options are available. The stylish, elegant design accommodates
painting of its “Designer Series” cover. The necessary mounting hardware (for the
drywall option) is provided with each model.
Back Box Mounting
Back box mounting, shown after this paragraph, is typically used at new construction
sites. The optional back box, BB-1600, includes the necessary hardware, brackets,
and electrical box, which provides a secure enclosure that, can be fastened directly to
the mounting surface. This mounting method is optional and requires the BB-1600
(sold separately). Details for installation are provided in the latest revision of the
BB-1600 Installation Guide (Doc. 5835).
Back Box Mounting
BB-1600
(INSTALLED)
DRYWALL
TOUCHPANEL
COVER
PAN HEAD SCREWS
Drywall Mounting
Each Series 1600 Touchpanel is provided with four metal mounting plates (two
small and two large) and eight mounting screws to fasten the panel to a mounting
surface without an electrical box. Complete the following installation procedure in
the order provided. The only tools required are a pencil (or equivalent), drywall saw
(or equivalent), a Phillips tip screwdriver, a drill with a 5/16” bit, and a drill with a
#20 bit. Refer to the illustration after this paragraph as needed.
6 Series 1600 Wired Touchpanels Operations & Installation Guide - DOC. 5836A