using the “Live Update on Startup” option in the registry.
Prevent user from clicking the “Setup Net ID’s” button too quickly after exiting the
“Setup Net ID’s” dialog. This could cause problems.
v1.5.8 (BETA)
Fixed bug (introduced in v1.5.7) where Load Wiring and Enclosure reports did not
display properly
Fixed potential SIMPL Windows crash during program generation
Improved sorting in “Finish View” such that items are now sorted by room and name,
but displayed information remains the same in all cases (only sort order changes).
Improved sorting used when Setting Network ID’s by adding a leading zero before
the slot number (where appropriate). This ensures, for example, that a module in
“Slot 09” will properly be listed before a module in “Slot 10”.
When an item is moved from one room to another, the tree in the Finish View is
properly updated.
Set minimum required VTPro-e version to v3.4.1.6 (required to work properly with
new templates).
Remember the size of the tree in Finish View between sessions of D3 Pro.
Properly linked Help buttons on Bill Of Materials and Remote System properties
dialogs.
Fixed bug (introduced in v1.5.x) where editing a circuit name in the Load Schedule
tree would fail if that circuit had a “controlled circuit number” assigned.
Fixed bug where an expression which referenced a deleted device would abort the
program generation process.
Fixed bug where “Detached” in-wall dimmers were not properly converted into
“standard” dimmers with the “Detached” property set to “true”.
Fixed bug where message boxes stemming from the Edit Step dialog could appear
behind the dialog when working in VTPro-e, thus making the application appear to be
stuck.
Removed warning message about missing “Global Subpage Reference” when
building touchpanels
Added text in Programming View to indicate when a given “Run Global Preset” step
will cause the lights to flash, or when a given “Cancel Global Preset” step will cause
the lights to be restored to their previous levels.
Fixed minor bug where button feedback controls were shown when you edited a
project in VTPro-e, but had not clicked on any object yet.
Fixed minor asthetic bug where toolbar would not look right while app was loading.
v1.5.7 (BETA)
Fixed bug (introduced in 1.5.x) where device names would not always appear
correctly during Network Setup
Fixed bug where sometimes moving devices to another room would not update the
underlying Location field in SIMPL Windows, which would cause incorrect locations
to show up during Network Setup
Changed naming convention used for CLX-series dimmers in Finish View and
Network Setup. Should make devices easier to identify.
Removed Cut/Copy/Paste Global Preset options, as implementation was not
complete
Fixed bug where copied logic containing conditionals would not always paste
correctly
Removed ability to edit “Controlled Circuit Number” from the Programming View (in
the “View Lighting” grid). It still appears in the grid, but it cannot be edited.
v1.5.6 (BETA)