Seitenansicht 35
Added SW-WMC with VerificationMethod=None and
Version=1.
ComServer (1.07.00)
Added auto purge to disk of debug logs. Polls once a minute
for no session activity, when this occurs it checks the
current memory allocated for logs and if greater than the
limit specified (100MB currently) it dumps them to disk and
frees all memory.
Added "Open Log folder" menu item.
CmVptlib32 (1.07.00)
In FollowProgramRestart, prompt was being asked for which
was disrupting the data stream. This was changed to only
get it from the result cache. Also added a call to get the
prompt (top populate the cache) at the start of program
load.
Fixed Switch-To/Retry problem. Cancel mechanism was
working correctly, but dynamic timeout evaluation was
sometimes try to evaluate timeouts even if it was not
connected. Added condition to only perform this is the com
state is connected. Also default enabled state was true.
Fixed Dynamic Timeout evaluation to not re-evaluate
timeouts while in passto or passthrough mode.
Added diagnostic info on reconnect and redetct after loss of
ethernet connection with error 10053. Checks, error log,
uptime and proguptime.
Fixed bug in FileSystemIsFile which would cause a failure
for files with an embedded comma. A paramater was being
passed as a string causing a reparse which split the
filename in two.
Added devices section versioning so that multiple device
sections will not get merged.
Fixed bug in FileSystemInitialize - uninitialized variable.
Possibly causing the code to exit prematurely. Same bug in
both 2-Series and TPS methods.
FileSystemInitialize for TPS method changed to handle a
possible confirmation prompt. Will work either way. This is
to handle the 3.XXX FW series of the legacy TPS panels.
Added ZipFileXXX abilities to compress, decompress, and
get file lists from zip files.
Extended timeout for "cards -force" command to
TIMEOUT_REALLY_SLOW_QUERY (15s base).
Extended timeout for "progcom" command to
TIMEOUT_SLOW_QUERY (5s base).
ProductVerifyPresence for ML-500/600 was not working all
the time. Extended wait time to 200ms and retures to 15 *
3. Seems it takes the remote ~5s to wake up.