Video Sensor Module Crestron ST-VS
Setup
Identity Code
Refer to the note on page 11 for a
definition of Viewport.
All equipment and user interfaces within the network require a unique identity code
(Net ID). These codes are two-digit hexadecimal numbers from 03 to FE. The Net
ID of each unit must match an ID code specified in the SIMPL Windows program.
Refer to “Setting the Net ID in Device Settings” on page 10 for details of the SIMPL
Windows procedure.
The Net ID of the ST-VS has been factory set to 3C, The Net IDs of multiple ST-
VSs in the same system must be unique. Net IDs are changed from a personal
computer (PC) via the Crestron Viewport.
NOTE: For detailed information on establishing communication between the PC
and control system, refer to “Communication Settings” on page 11. If
communication cannot be established, refer to the “Troubleshooting
Communications” section in the respective Operations Guide for the control system.
Use the following instructions to set or change the Net ID.
1. Ensure that the device requiring a Net ID change is the only unit connected
to the control system.
2. Open the Crestron Viewport.
3. From the Viewport menu, select Functions | Set Network ID. The software
checks the baud rate and then opens the "Set Network ID" window.
4. In the "Set Network ID" window, select the device requiring a Net ID
change from the Current Network Devices text window.
5. Select the new Net ID for the device from the Choose the new network ID
for the selected device (Hex): text box.
6. Click Set ID to initiate the change. This will display the "ID command has
been sent" window.
7. In the "Command Complete" window, click OK.
8. In the Current Network Devices text window, verify the new Net ID code.
9. In the "Set Network ID" window, click Close.
NOTE: The new Net ID code may also be verified by selecting Diagnostic | Report
Network Devices in the Viewport (alternately, select F4).
10. Repeat this procedure for each additional network device requiring a Net ID
change.
Hookup
Refer to the following hookup diagram. Other than making the power connection
last, complete the connections in any order. RCA cables are not supplied.
CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do
so could cause equipment damage or void the Crestron warranty.
6 Video Sensor Module: ST-VS Operations Guide – DOC. 5767A