Crestron Isys™ TPS-5000L 12 Inch Lectern/Wall Mounted Touchpanel
Calibration Menu
CALIBRATION MENU
Calibration of the touchscreen is required if the active touch area of a button does
not coincide with the button's image. Select the Touch Screen Calibration
utton to
display the CALIBRATION MENU, shown to the left. The CALIBRATION MENU
offers the choice to initiate calibration with the Perform Calibration button or
return to the previous screen with the Return button. Choose an option by touching
the correct button.
If you proceed to calibrate the touchpanel, the screen displays the message "Touch
Upper Left" centered on the panel with a cross hair in the corner. Touch the cross
hair in the corner of the screen to initiate calibration. Another message, "Touch
Upper Right", appears with a cross hair in the correct corner. Touch the corner of the
screen. A final message, “Touch Lower Right”, appears with a cross hair in the
correct corner. Touch the corner of the screen to conclude calibration and return to
the MAIN MENU.
NOTE: When touching the screen during calibration, be as accurate as possible.
Use the tip of a capped pen or the eraser end of a pencil. To cancel calibration and
return to the CALIBRATION MENU without saving calibration data, create a
calibration error by touching the screen in an area that is opposite from the instructed
area.
Setup Menu
SETUP MENU
To access the SETUP MENU, shown to the left, press the Setup button from the
MAIN MENU. The SETUP MENU offers a series of buttons, which opens
additional menus and displays, which are detailed in subsequent paragraphs. Many
touchpanel options (i.e., standby timeout and brightness) are available directly from
the SETUP MENU and are explained in the following paragraphs. Other setup
parameters (i.e., interface, RS-232, audio, RGB, and video) use additional menus
and are detailed in subsequent paragraphs as well. After setup parameters have been
set, select the Return button to return to the MAIN MENU.
NOTE: The current CRESNET ID setting is displayed in the upper left corner of
the SETUP MENU.
NOTE: All touchpanel settings are automatically saved in non-volatile memory.
NOTE: The Ethernet, RGB, and Video buttons will only be displayed if the
respective TPS-ENETL, TPS-XVGAL or TPS-VIDL-1/2 cards are installed.
NOTE: If the TPS-VIDL-2 is installed, two video buttons will be displayed; “Video
1” and “Video 2”. Press the button for the respective video source.
The touchpanel display can be turned off (standby mode) when not in active use.
STANDBY TIMEOUT, located in the middle of the SETUP MENU, can turn off
the touchpanel when it is inactive for a specified time frame (minutes, shown as
XXX in the illustration). When the touchpanel is activated, the last screen to be
displayed reappears. Minutes can vary from 0 to 120, where 0 disables the timeout.
DOWN and UP buttons decrease and increase the timeout, respectively.
Screen brightness may need to be altered because of ambient light conditions or
personal preference. BRIGHTNESS, located in the lower left corner of the SETUP
Operations Guide - DOC. 5783A 12 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-5000L • 9