Crestron e-Schedule Programmer’s Guide
dig o85 – o104
Transport controls for SourceA-SourceF devices.
dig i85 – i104
Feedback of the specified source.
NOTE: If a join number that specifies a Pass-Through signal is also used by
the Scheduler (i.e., join number 21, which identifies SourceA on the
“Destination” ActiveCNX Interface), the Pass-Through takes priority and the
original command is ignored. A signal cannot be configured as both a Pass-
Through and a Global Event. For example, to pass a LIGHTS-ON command
from a Web browser to a room and to schedule it as a global event would
require two separate join numbers.