Crestron ST-LT Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Vernetzung Crestron ST-LT herunter. Crestron ST-LT Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 2

CRESTRON 4. Notice the list of current network devices in the dialog box. Highlight the ST-LT. 5. The factory set NET ID of the ST-LT (1C) appears

Seite 3 - Contents

CRESTRON Changing the NET ID - ST-LT Workshop Screens (2 of 3) 5. Enter a new NET ID code (in two-digit hexadecimal format) and depress ENTER. The

Seite 4

CRESTRON 4. Slide the top cover toward the back panel while holding the ST-LT in place until the cover is free. 5. Locate the dip switch and noti

Seite 5 - Lutron Interface

CRESTRON Preparation for Use Refer to the two hookup diagrams below. The first diagram illustrates the connections to SmarTouch STS. The second diag

Seite 6 - ST-LT Ports

CRESTRON Programming Using STS/VTW Software NOTE: The following description assumes that the reader has some knowledge of STS/VTW software. If not,

Seite 7 - LUTRON DESCRIPTION

CRESTRON Select Open and Project from the File menu to open the touchpanel project file. For this sample, the project has been named LUTRON.PRJ. Th

Seite 8 - ST-LT Indicators

CRESTRON The macro in this sample shall address MAIN-UNIT-2 and select ZONE-1-UP. 8. A macro is created by adding the appropriate commands and del

Seite 9 - Leading Specifications

CRESTRON SIMPL SIMPL is CRESTRON’s programming language designed for easy implementation of the control system requirements. The best representation

Seite 10 - CRESTRON

CRESTRON ST-LT Workshop Screens (2 of 4) ST-LT Workshop Screens (3 of 4) ST-LT Workshop Screens (4 of 4) The ST-LT is defined as an “ST-COM, Port

Seite 11

CRESTRON The data field contains the command protocol for the Grafik Eye system. A description of commands, their operation, and examples are provid

Seite 13 - Preparation for Use

CRESTRON Problem Solving Troubleshooting The table below provides corrective action for possible trouble situations. If further assistance is requir

Seite 14 - Programming

CRESTRON Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service witho

Seite 15 - Lighting Page Sample

CRESTRON Appendix: GRAFIK Eye Commands NOTE: This entire appendix is a reprint of Lutron’s technical reference material. Format for Commands The RS

Seite 16 - Function Dialog Box

CRESTRON Examples: :A21<CR>Select scene 2 on GRAFIK Eye Main Unit 1.:AG45 A78<CR>Select scene 16 on GRAFIK Eye Main Units 4 and 5; selec

Seite 17 - Workshop

CRESTRON Example of Response: <CR><LF>~:ss2L0MAR95 1 OK<CR><LF> Main Unit A1 is in scene 2

Seite 18

CRESTRON (D) Zone Lower This command causes the zones of the selected GRAFIK Eye Main Units to gradually decrease in intensity. The first parameter

Seite 19

CRESTRON Examples: :C<CR>Stop all zones on all GRAFIK Eye Main Units that are ramping up. :C E<CR>Stop all zones that are being raised o

Seite 20 - Problem Solving

CRESTRON 0 = no schedule active1 = "weekday" schedule2 = "weekend" schedule3 = "special 1" schedule4 = "special 2

Seite 21 - Return and Warranty Policies

CRESTRON Example: :QS<CR>Start super sequence. (QP) Super Sequence Pause This command stops the preprogrammed super sequence that is running a

Seite 22 - GRX-AV-RS232 Command List

CRESTRON This page intentionally left blank. Operations Guide - Doc. 5694 Lutron Interface

Seite 23 - (G) Request Scene Status

CRESTRON Contents Lutron Interface 1 Description...

Seite 24 - (ZL) Zone Lock

CRESTRON This page intentionally left blank. 26 • Lutron Interface Operations Guide - Doc

Seite 25 - Zone Raise Stop

CRESTRON Operations Guide - Doc. 5694 Lutron Interface • 27 This page intentionally left blank.

Seite 28 - (QC) Super Sequence Resume

CRESTRON Lutron Interface Description Functional Description There are two CRESTRON Lutron Interface configurations available: ST-LT and STI-LT. Con

Seite 29

CRESTRON ST-LT Physical Views ST-LT Ports A number of ports are provided on the back of the ST-LT. Each has a silk-screened label. Refer to illustr

Seite 30

CRESTRON NET These two 6-pin, 6-position RJ11 modular jacks are used to connect the ST-LT module to either the SmarTouch STS or CRESNET II remote co

Seite 31

CRESTRON ST-LT Indicators There are seven LED indicators located on the front panel of the ST-LT. Refer to illustration and descriptions below. ST-

Seite 32

CRESTRON Leading Specifications The table below provides a summary of leading specifications for the ST-LT module. Dimensions and weight are approxi

Kommentare zu diesen Handbüchern

Keine Kommentare