Crestron PAC2 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Vernetzung Crestron PAC2 herunter. Crestron PAC2 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Operations Guide

Crestron PAC2 Professional Automation Computer Operations Guide

Seite 2

Professional Automation Computer Crestron PAC2 PAC2 Physical Views 14.00 in(35.56 cm)7.40 in(18.80 cm)3.75 in(9.52 cm)Top ViewFront ViewZ-Bus SlotY

Seite 3 - Contents

Crestron PAC2 Professional Automation Computer Ports/Connectors The ports/connectors provided on the top and front panel of the PAC2 are described

Seite 4

Professional Automation Computer Crestron PAC2 received between the “G” connection and the “L” or “R” connection (R is used in a double-wide enclos

Seite 5 - Computer: PAC2

Crestron PAC2 Professional Automation Computer NOTE: The LAN LEDs are active only if the optional single port or dual port Ethernet card (which is

Seite 6

Professional Automation Computer Crestron PAC2 Powering a Hub Segment Pair In the illustration above, one of the supplied 3-pin mini connectors wi

Seite 7 - Specifications

Crestron PAC2 Professional Automation Computer File System Structure TOP LEVEL SECONDARY LEVEL DESCRIPTION\ Root of the file systemDISPLAYLegacy di

Seite 8

Professional Automation Computer Crestron PAC2 Expandable Memory (Compact Flash) The on-board 36MB memory of the 2-Series integrated dual bus contr

Seite 9 - Physical Description

Crestron PAC2 Professional Automation Computer Setup Mounting the PAC2 in the Crestron Automation Enclosure (CAEN) CAUTION: The CAEN houses equip

Seite 10 - PAC2 Physical Views

Professional Automation Computer Crestron PAC2 Mounting the PAC2 in the CAEN 8B 1/4 inch screwCLX-Series ModulePAC2Double-wideCAEN AC Power Conne

Seite 11 - Ports/Connectors

Crestron PAC2 Professional Automation Computer PAC2 AC Power Source Assembly and Connection Diagram CRESTRONRailFromHOTFromNEUTRALNEUTRALTo GNDStri

Seite 12 - Indicators

This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647

Seite 13 - Reset Buttons

Professional Automation Computer Crestron PAC2 Bussing Strip Installation The PAC2 is supplied with two brass bussing strips to facilitate commonin

Seite 14 - On-Board Memory

Crestron PAC2 Professional Automation Computer When calculating the wire gauge for a particular network run, the length of the run and the power fa

Seite 15 - Volatile

Professional Automation Computer Crestron PAC2 NOTE: Since the plug on the power supply cord is used to disconnect power from the unit, the socket-

Seite 16 - Industry Compliance

Crestron PAC2 Professional Automation Computer Establishing Communication with the PAC2 Before uploading a program to the control system or perform

Seite 17 - Enclosure (CAEN)

Professional Automation Computer Crestron PAC2 “Port Settings” Window: Default PC Settings for RS-232 Communication with the PAC2. To verify commu

Seite 18 - Quantity/Description Part #

Crestron PAC2 Professional Automation Computer Once the cable connections are made, open the Crestron Viewport and click Setup | Communication Sett

Seite 19 - CRESTRON

Professional Automation Computer Crestron PAC2 Troubleshooting Communications Use the following checklist if communication cannot be established wi

Seite 20 - Network Wiring

Crestron PAC2 Professional Automation Computer f. Reinitialize the unit by recycling the power or pressing the HW-R button. If the connection is e

Seite 21

Professional Automation Computer Crestron PAC2 If any errors are generated during programming, they will be displayed in the Messages field. You ca

Seite 22 - EXPANSION

Crestron PAC2 Professional Automation Computer With TCP/IP, type the IP address of the PAC2. If the panel is connected directly to a COM port on t

Seite 23 - Serial Connection

Crestron PAC2 Professional Automation Computer Contents Professional Automation Computer: PAC2 1 Introduction ...

Seite 24 - TCP/IP Connection

Professional Automation Computer Crestron PAC2 • Immediately after compiling the program, you will be prompted to transfer the file to the PAC2. •

Seite 25 - “Port Settings” Window

Crestron PAC2 Professional Automation Computer As shown on the previous page, click Yes to retrieve the program from Compact Flash, or No to retrie

Seite 26 - Viewport Message

Professional Automation Computer Crestron PAC2 2. Select the network ID of the touchpanel, as set in SIMPL Windows and configured on the touchpane

Seite 27 - Control System

Crestron PAC2 Professional Automation Computer Send Generic Files-permit you to choose between internal flash and compact flash when selecting prog

Seite 28

Professional Automation Computer Crestron PAC2 Console Commands That Work with Compact or Internal Flash The following commands have been modified

Seite 29 - Program to the PAC2

Crestron PAC2 Professional Automation Computer Programming Software You can create a program to control the PAC2 control system using the Crestron

Seite 30 - “Retrieve Program” Window

Professional Automation Computer Crestron PAC2 PAC2 Device Library Symbols Configuration Manager is where programmers “build” a Crestron control sy

Seite 31

Crestron PAC2 Professional Automation Computer Description Internal configuration of a Versiport +5V2Kpullup1o1S1-AS1-BAUsed for analog input.Can b

Seite 32

Professional Automation Computer Crestron PAC2 Analog Input Mode In analog input mode, the Versiport is typically tied to a resistive load (such as

Seite 33 - Advanced Console Commands

Crestron PAC2 Professional Automation Computer To add a device to the system, expand the C2 Net-Device slot and double-click the desired Net ID, or

Seite 35 - Programming Software

Professional Automation Computer Crestron PAC2 2. Click Project | Edit Program Header. 3. Click 2-Series in the Target Control System Classes list

Seite 36 - PAC2 Device Library Symbols

Crestron PAC2 Professional Automation Computer Problem Solving Problems may occur with the 2-Series automation control system itself or there may b

Seite 37

Professional Automation Computer Crestron PAC2 2. Open Viewport and select Setup | Communication Settings to open the “Port Settings” window. 3.

Seite 38

Crestron PAC2 Professional Automation Computer Serial Communication Difficulties with Other Devices Connected to the Control System It is possible

Seite 39 - Systems

Professional Automation Computer Crestron PAC2 Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information o

Seite 40

Crestron PAC2 Professional Automation Computer Software License Agreement This License Agreement (“Agreement”) is a legal contract between you (eit

Seite 41 - CORRECTIVE ACTION

Professional Automation Computer Crestron PAC2 If You are a business or organization, You agree that upon request from Crestron or its authorized a

Seite 42 - Battery Replacement

Crestron PAC2 Professional Automation Computer Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned

Seite 43 - “Passthrough Mode” Window

Crestron Electronics, Inc. Operations Guide – DOC. 5941 15 Volvo Drive Rockleigh, NJ 07647 12

Seite 44 - Future Updates

Crestron PAC2 Professional Automation Computer Professional Automation Computer: PAC2 Introduction Features and Functions The Professional Automati

Seite 45 - Software License Agreement

Professional Automation Computer Crestron PAC2 available via Crestron’s single-port C2ENET-1 and dual-port C2ENET-2 Ethernet cards. The PAC2 offer

Seite 46 - CRESTRON LIMITED WARRANTY

Crestron PAC2 Professional Automation Computer Specifications Specifications for the PAC2 are provided below. PAC2 2-Series Automation Control Sys

Seite 47 - Return and Warranty Policies

Professional Automation Computer Crestron PAC2 3. Optional Z-BUS Cards: Single port 10/100 Ethernet, Dual Port WAN-LAN-10/100 Ethernet, or Dual Po

Seite 48

Crestron PAC2 Professional Automation Computer Physical Description The PAC2 automation control system is housed in a gray and black enclosure with

Kommentare zu diesen Handbüchern

Keine Kommentare