Central heating system
Product Description
CX9020-0111 TwinCAT PLC, Windows CE
- CX1800-1052 Windows CE, BACnet image *
* optional BACnet component
KL1809 16-channel digital input 24 V DC
F12
F13
F14
M231_2
M231_3
M232_2
M232_3
M233_2
M233_3
M234_2
M234_3
M161_2
M161_3
M162_2
M162_3
Maximum boiler pressure
Minimum boiler pressure
Boiler temperature safety limiter
Primary pump fault
Primary pump operation
Heating circuit 1 pump fault
Heating circuit 1 pump operation
Heating circuit 2 pump fault
Heating circuit 2 pump operation
Heating circuit 3 pump fault
Heating circuit 3 pump operation
Storage charge pump fault
Storage charge pump operation
Circulation pump fault
Circulation pump operation
KL6781 M-Bus master terminal
Z1
Z2
Z3
Z4
Heat meter
Service water meter
Gas meter
Power meter
KL3208-0010 PT1000 8-channel analog input
B001
B081
B091
B082
B092
B083
B094
B084
Boiler temperature
Primary hydraulic gate flow temperature
Primary hydraulic gate return temperature
Secondary hydraulic gate flow temperature
Secondary hydraulic gate return temperature
Hot water flow temperature
Heating circuit 1 return temperature
Heating circuit 1 flow temperature
KL3208-0010 PT1000 8-channel analog input
B095
B085
B096
B086
B14
B15
B16
B01
Heating circuit 2 return temperature
Heating circuit 2 flow temperature
Heating circuit 3 return temperature
Heating circuit 3 flow temperature
Hot water boiler, top
Hot water boiler, bottom
Hot water service water temperature
Ambient temperature
KM2652 2-channel relay module 230 V AC, 6 A, manual/automatic
operation
Y00
HBU2
M231_1
M232_1
M233_1
M234_1
M161_1
M162_1
Boiler clearance
Boiler operation
Primary pump clearance
Heating circuit 1 pump clearance
Heating circuit 2 pump clearance
Heating circuit 3 pump clearance
Storage charge pump
Circulation pump
KM4602 2-channel analog output 0…10 V, manual/automatic
operation
Y00
Y201
Y202
Y203
Y204
Boiler modulation
WWB control valve
Heating circuit 1 control valve
Heating circuit 2 control valve
Heating circuit 3 control valve
KL9010 End terminal
outgoing
circuit
heating circuit 3heating circuit 2heating circuit 1
ventilation
T
B01
F11
M231
B081 B082
B083
Y201
B15
B16
M162
B084
B094 B085
B095 B096
M232
Y202
M233
Y203
B086
M234
Y204
B14
M161
B091 B092
F12
F13
F14
B001
boiler
HS
Y00
T T
TT
T
T
T
T
T
T
T
M
M
F
F
F
F
T T
M
T T
M
Central heating system
New Automation Technology
Beckhoff
We reserve the right to make technical changes.
59
Seitenansicht 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 79 80

Kommentare zu diesen Handbüchern

Keine Kommentare